GuruMCQs.com provides all updated Mechanical Engineering Multiple Choice Questions (MCQs). The most frequently repeated mechanical MCQs section is frequently encountered in FPSC, PPSC, ETEA, NTS, Army, Navy, Air Force, educators, and various other competitive exams, as well as government and private job assessments. Most repeated mechanical engineering MCQs cover topics like Engineering Materials, Fluid Mechanics, Hydraulic Machines, Machine Design, Engineering Mechanics, Nuclear Power Plants, Steam Boilers, Engines, Nozzles, Turbines, Compressors, Gas Turbines, Jet Engines, Thermodynamics, Engineering Metrology, Heat Transfer, etc. Preparing with these MCQs can significantly contribute to your success in government job exams and interviews. Whether you are aiming to establish a career in engineering or seeking to enhance your existing skills, the Mechanical Engineering MCQs at www.gurumcqs.com serve as a valuable resource. Stay committed to regular practice and empower yourself with the knowledge needed to excel in your academic and professional endeavors.

**181. In a flooded evaporator refrigerator, an accumulator at suction of compressor is used to:**
– **A. collect liquid refrigerant and prevent it from going to compressor**
– B. detect liquid in vapour
– C. superheat the vapour
– D. collect vapours
– E. increase refrigeration effect

**182. Accumulators should have adequate volume to store refrigerant charge at least:**
– A. 10%
– B. 25%
– **C. 50%**
– D. 75%
– E. 100%

**183. A refrigeration cycle operates between condenser temperature of +27°C and evaporator temperature of -23°C. The Carnot coefficient of performance of cycle will be:**
– A. 0.2
– B. 1.2
– **C. 5**
– D. 6
– E. 10

**184. In vapor compression refrigeration system, refrigerant occurs as liquid between:**
– **A. condenser and expansion valve**
– B. compressor and evaporator
– C. expansion valve and evaporator
– D. compressor and condenser
– E. none of the above

**185. Efficiency of a Carnot engine is given as 80%. If the cycle direction be reversed, what will be the value of COP of reversed Carnot cycle:**
– **A. 1.25**
– B. 0.8
– C. 0.5
– D. 0.25
– E. none of the above

**186. Aqua ammonia is used as refrigerant in the following type of refrigeration system:**
– A. compression
– B. direct
– C. indirect
– **D. absorption**
– E. none of the above

**187. If a heat pump cycle operates between the condenser temperature of +27°C and evaporator temperature of -23°C, then the Carnot COP will be:**
– A. 0.2
– B. 1.2
– **C. 5**
– D. 6
– E. 10

**188. In a refrigeration cycle, the flow of refrigerant is controlled by:**
– A. compressor
– B. condenser
– C. evaporator
– **D. expansion valve**
– E. all of the above

**189. The lower horizontal line of the refrigeration cycle plotted on pressure-enthalpy diagram represents:**
– A. condensation of the refrigerant vapour
– **B. evaporation of the refrigerant liquid**
– C. compression of the refrigerant vapour
– D. metering of the refrigerant liquid
– E. none of the above

**190. Freon group of refrigerants are:**
– A. inflammable
– B. toxic
– C. non-inflammable and toxic
– D. non-toxic and inflammable
– **E. non-toxic and non-inflammable**

Leave a Reply